Simplex Addressable Smoke Detector

Request Callback

₹ 2750 / Piece Get Latest Price

Product Brochure
Protocolsimplex
Detector TypePhotoelectric
Operating Voltage18-32
Base TypeIsolator Base
Alarm IndicationLED 360 Degree
Addressing MethodDIP Switch
ApprovalsEN54
Housing ColorWhite
Operating Temperature-10 to 50 C

The Simplex 4098-9714 is an addressable photoelectric smoke sensor designed for use with Simplex IDNet and MAPNET II two-wire communications. Using TrueAlarm analog sensing technology, the detector digitally transmits real-time smoke data to the control unit for precise analysis and reduced nuisance alarms.

This model features a 360° smoke entry design for improved detection response from any direction and built-in insect screening to help maintain sensing chamber integrity. The control panel automatically adjusts sensitivity to compensate for dust and environmental changes, improving long-term reliability.

Selectable sensitivity levels include 0.2%, 0.5%, and 1% per foot for special applications, with standard operation ranging from 1.25% to 3.1% per foot depending on panel programming.

The 4098-9714 is compatible with Simplex 4007ES, 4010, 4010ES, 4100ES, 4100U, and 4008 Series control units with reduced feature set. It mounts to compatible TrueAlarm bases and is listed to UL 268 7th Edition. Operating temperature range is 15°F to 122°F.

Ideal for commercial fire alarm systems requiring intelligent smoke detection and panel-based sensitivity control.

MORLEY IAS ADDRESSABLE MONITOR MODULE

Request Callback

₹ 2900 / Piece Get Latest Price

Product Brochure
BrandMORLEY IAS
Model Name/NumberMI-DMMI

Minimum order quantity: 5 Piece

The MI-DMMI and MI-DMM2I monitor modules are used with the Morley-IAS intelligent fire alarm control panels to provide a single or dual input circuit from external devices. Each input is continuously monitored for normal, open circuit and alarm conditions. Changes to the status of the input circuits are communicated to the panel where the appropriate actions may be undertaken. The MI-DMMI requires a single address and the MIDMM2I two addresses of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel indicated by a pulsing LED every successful communication. The MI-DMMI and MI-DMM2I use a unique mechanical design allowing each module to be mounted either in a wall box (M200E-SMB) or on a DIN rail (using M200E-DIN). Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the output. For ease of installation, testing and maintenance, the field wiring terminals are of a plug in design. FEATURES • Single or dual inputs • DIN rail mounting option • Surface mounting option • Tri-colour LED status indication • Built-in short circuit isolators • Visible address selector switches • LED status visible in 2 planes • Plug in connectors • Approved to GEA GEI 1-082 and CEA GEI 1-084

Honeywell Conventional Smoke Detectors

Request Callback

₹ 850 / Piece Get Latest Price

Product Brochure
Alarm Sensor TypePhotoelectric
Conventional Or AddressableCONVENTIONAL
Product TypeSMOKE DETECTOR
BrandSYSTEM SENSOR BY HONEYWELL
ColorWHITE
Country of OriginMade in India

Minimum order quantity: 10 Piece

The 2351EC photoelectric smoke detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. Combined with the latest state of the art optical chamber the detector provides efficient and accurate detection of fires with a high level of resilience to nonfire environmental influences. The 2351EC detector is backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The 2351EC detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. ‘Drift compensation’ algorithms are one of the key features of the 2351EC detector. These algorithms ensure a consistent alarm sensitivity threshold for periods between service intervals. This provides the user with both a reduction in the frequency of nuisance alarms and maintenance savings by extending the p

EST Quick Start - Fire Alarm System

Request Callback

₹ 125000 / Unit Get Latest Price

ColorWhite
Automation GradeAutomatic
Wall MountedYes
Voltage220
Installation ServiceYes
ConditionNew
Relay OutputsSupervisory Relay, Alarm Relay, Trouble Relay
Supplying Edwards Fire Alarm Systems                   .

Honeywell Morley smoke Detector

Request Callback

₹ 2300 / Piece Get Latest Price

Product Brochure
Product TypeAddresable smoke detector
Usage/ApplicationIndustrial
BrandMorley Ias
Alarm Sensor TypePhotoelectric
ColorWhite
Automation GradeAutomatic

Optical-thermal smoke detector

The optical-thermal sensor uses thermal assistance to the core photoelectric smoke detector to give enhanced false alarm immunity and faster response to a wide range of incipient fires. The plug-in unit combines two separate sensing elements that are managed by embedded software to act as a single unit.

Multi sensor combined optical smoke sensor and thermal sensor in a single housing Requires either MOFMIB501APIV or B5241EFT base for mounting.

Cooper Addressable Analogue Optical Smoke Detector

Request Callback

₹ 1900 / Piece Get Latest Price

Product Brochure
Product TypeAddressable Analogue Optical Smoke Detector
BrandCooper
Usage/ApplicationOffice Buildings
Alarm Sensor TypeOptical
Colorwhite

Minimum order quantity: 5 Piece

Main Features
  • Soft addressed
  • Integral short circuit isolator
  • Single address
  • Wide range of sensor types
  • 360° visibility LED using lightpipe technology
  • Drift compensation
  • Aesthetically pleasing
Marketing Information

The optical sensor (CAP320) is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles.

Honeywell Morlay addressable Manual Call Point

Request Callback

₹ 3900 / Piece Get Latest Price

Product Brochure
BrandMorley Ias
Usage/ApplicationFire Alarm System

Call Points HM-MCP-GLASS


The call point is an addressable break glass manual call point which has a simple rotary decade switch at the rear of the unit for addressing.
A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.
The HM-MCP-GLASS Call Point is designed to provide a manual alarm interface to Morley IAS’s fire alarm control panel.

Edward photo Electronic Smoke Detector

Request Callback

₹ 2220 / Piece Get Latest Price

Product Brochure
Product TypeSMoke Detector
BrandEdward
Usage/ApplicationOffice Buildings
The EST Signature Series Model SIGA-PS Intelligent Photoelectric Smoke Detector gathers analog information from its smoke sensing element and converts it into digital signals. SIGA-PS on- board microprocessor measures and analyzes these signals.

RAVEL SMOKE DETECTOR

Request Callback

₹ 1200 / Piece Get Latest Price

Product Brochure
BrandRavel
Product TypeSmoke Detector
Usage/ApplicationOffice Buildings

The microprocessor based 4 Zone CE mark conventional fire alarm control panel is a standalone system, with 16 X 2 LCDcharacter, 4 zones detection circuit,3 common potential free contacts & a common NAC sounder output, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection.
RE-104 fire alarm control panel is designed with unique protocol to be used for small commercial building and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability.

Key Features:

  • Switch Mode Power Supply
  • Modular Construction, Serviceable
  • Surface Mount Technology
  • Battery polarity & deep discharge protection
  • As per IS -15908: 2011 Standard
  • 16 X 2 Dot Matrix LCD Display
  • Standby battery backup with built in charging
  • Fire / Fault status in unambiguous colored LED indication
  • Switch Mode Power Supply
  • Tactile Keypad for easy panel operation
  • System on indication
  • Main, Standby status indication
  • Low Battery visual warning with audible tone
  • Relay output for actuators for Fire and Fault
  • Lamp Test facility
  • Zone wise one man walk Test Facility
  • Zone wise Isolation facility with loop voltage cut off
  • Compatible to all type of Conventional Detectors
  • Optional Zone Wise Sounder / Zone Wise Contact

Honeywell Morley Sounder Red

Request Callback

₹ 4500 / Piece Get Latest Price

Product Brochure
Usage/ApplicationAll Use
ColorRed
wall mount sounder is a high quality loop powered device designed to alert building occupants of an emergency. It utilizes the System Sensor B501AP base for improved installation flexibility. When triggered by the fire panel its powerful sounder gives an audible warning. A choice of output levels and tones make the device suitable for a wide variety of applications.

GST Intelligent Photoelectric Smoke Detector, DI-9102E

Request Callback

₹ 1650 / Piece Get Latest Price

Product Brochure
Alarm Sensor TypePhotoelectric
Product TypeIntelligent Photoelectric Smoke DetectoR
Usage/ApplicationOffice Buildings
Country of OriginMade in India

Minimum order quantity: 10 Piece

Transform your fire safety measures with the GST Intelligent Photoelectric Smoke Detector, DI-9102E. This Conventional Smoke Detector by GST boasts a standby current of <0.8 mA and an indicator that flashes in polling and illuminates in alarm. With a sensitivity of 2 and adherence to EN54-7 and LPCB standards, this model, DI-9102E, offers a range of 1-242 and a mounting hole distance of 45-75 mm. Enjoy key features like electrically addressed modification, drift compensation, self-diagnostic capabilities, reed switch testing, and a fire LED for 360-degree visibility. Upgrade your safety system today.

Cooper Addressable Analogue Combined Photo Thermal Detector

Request Callback

₹ 2450 / Piece Get Latest Price

Product Brochure

Minimum order quantity: 5 Piece

Main Features
  • Soft addressed
  • Integral short circuit isolator
  • Single address
  • Wide range of sensor types
  • 360° visibility LED using lightpipe technology
  • Drift compensation
  • Aesthetically pleasing
Marketing Information

The photo-thermal sensor (CAPT340) will respond quickly to fast clean burning fires yet maintainthe advantage of optical sensors when detecting smouldering fires. The thermal enhancement of this sensor allows a higher alarm threshold which provides agreater rejection of false alarms. The sensor will alsoraise an alarm at temperatures exceeding 60ºC.
The CAPT340 has day/night modes available, programmeable from the site installer software. The day mode uses the heat aspect of the sensor for areas which may have smoky environments during, for example working hours. The night mode uses a combination of A2S and smoke detection. If not programmed, the sensor defaults to dual mode.

Honeywell HC35W45R2 35 Series 5MP IR MFZ WDR IP Dome Camera, 2.7-13.5mm Lens, White

Request Callback

₹ 17800 / Piece Get Latest Price

Product Brochure
Series50 series
Camera Resolution5MP
Camera TypeIP
IP RatingIP66/IP67
IR Range30 m
WDR120 dB WDR
WDR (Wide Dynamic Range)120 DB
Wide Dynamic Range120 DB
Digital Zoom5X
Connectivity TechnologyPOE
Country of OriginMade in India

Minimum order quantity: 2 Piece

  • Network camera - Helps achieve high-quality video results
  • Up to 2592 x 1944 resolution for surveillance in real-time
  • CMOS sensor is cheaper as compare to CCD and consumes less power while producing better HD videos
  • 13.50 mm maximum focal length provides incredible detail and how effective is your network camera
  • f/1.6 maximum aperture for productive capturing according to focal length and lighting conditions
  • 5x optical zoom ensures maximum surveillance productivity without compromising quality
  • Up to 164.04 ft of night vision
  • Infrared night vision type effectively captures visible footage without requiring any external sources of light
  • Varifocal lens type to ensure maximum surveillance dependability and optimal performance
  • DC power source type for your network camera provides maximum energy feasibility and added surveillance productivity

Morley-IAS loop isolator module MI-DISO

Request Callback

₹ 2600 / Piece Get Latest Price

Product Brochure
TypeAddressable
DIMENSIONS [MM] (H X W X D)93 x 94 x 23 (H x W x D
Country of OriginMade in India

Minimum order quantity: 2 Piece

The Morley-IAS loop isolator module is used on the Morley-IAS intelligent fire alarm control panels to protect the system against wire-to-wire short circuits on the analogue addressable loop wiring. The fault isolator modules should be placed between groups of sensors on the loop wiring to protect the loop if a short circuit fault occurs. If a short circuit fault occurs, the two isolators located either side of the short circuit fault will automatically sense the voltage drop, open their switches and remove the devices from the rest of the loop. If the line voltage then rises above a fixed threshold, indicating that the short circuit fault is removed, then the isolator module will automatically restore the power to the isolated group of devices. The MI-DISO isolator uses a unique mechanical design allowing each module to be mounted either in a wall box or on a DIN rail. Irrespective of the mounting method chosen, the address switch is both visible and accessible for selection. To help engineers in the maintenance and fault finding process, both the LEDs and the address switches can be viewed without having to remove the cover of the mounting box. The LEDs, being multi colour, provide diagnostic information regarding the status of the isolator.